CoolMaster 3000T is versatile bridge device connecting Toshiba VRF Air Conditioning
systems and any RS232 or USB capable device
like Home PC, Embedded PC or Home Automation Controller. Exposing
simple interface over RS232 communication line or USB bus, CoolMaster gains
user application full control on indoor units and provides access to VRF
system parameters. In other words CoolMaster hides complexity
of internal Toshiba Communication line (including very unique physical layer)
and instead gives simple, comprehensive, well documented protocol
running on popular RS232 or USB connection.
|
|
Features |
-
Easy to integrate with Home Automation Systems and PC applications
CoolMaster Interface is very simple and straightforward.
Implementation of software modules to support CoolMaster
is not complex at all.
-
Unified RS232 Interface
All CoolMaster products impose unified RS232 interface.
It means for example that home automation application
working on Toshiba VRF system with CoolMaster 3000T will work
exactly the same way on Sanyo VRF system with CoolMaster 2000S or Daikin with
CoolMaster 1000D and no special interface adaptation will be required to migrate from one
CoolMaster type to another.
-
Full Control over Indoor Units Operation
On/Off control, 
Cool, Heat, Fan, Dry mode selection, 
Set Temperature Control, 
Fan Speed Control, 
Swing Control (for wall mounted and cassette indoor units), 
Filter Reset Sign, 
Group Operations (All On, All Off)
-
Outdoor and Indoor Units Monitoring
Failure Alarms, Set point temperature, Operation status (on/off)
Operation mode (cool/heat/fan/dry), Fan speed (high/low),
Filter sign, Swing
-
System Diagnostics (An option that is available on demand)
Outdoor Units internal parameters: Condensing, Evaporation,
Ambient Temperatures, EV Opening, System Power Consumption (current),
Inverter Revolutions and others
Indoor Units internal parameters: Return air, Gas and Liquid
Temperatures, EV Opening
-
CoolMaster unit can be extended with additional Hardware modules
Up to 5-GPIO, RTC-Real Time Controller, Electronic Thermometer, Buzzer.
-
Field Upgradable
New Firmware can be uploaded via RS232 port. No need to open unit
to change it's functionality.
|
Block Diagram |
|
|
Compatibility List |
MCY-MAP..HT
|
MMU-AP..H |
MMU-AP..MH |
MMU-AP..WH |
MMY-MAP..T8
|
MMU-AP..YH |
MMD-AP..BH |
MMD-AP..H |
MMY-MAP..HT8
|
MMD-AP..SPH |
MMC-AP..H |
MMK-AP..H |
MMY-MAP..FT8
|
MML-AP..H |
MML-AP..BH |
MMF-AP..H |
|
MMD-AP..HFE |
|
|
Legend: 
-Outdoor Unit Type
-Indoor Unit Type
|
|
|
Documentation |
|
|
Applications |
-
Home Automation systems with
AMX
, 
Philips Pronto , 
Vantage Legrand , 
Crestron , 
ABB , 
Unitronix , 
LiteTouch , 
and other Controllers
-
VRV Monitoring System
|
|
Email Support |
|
|
Order On-line |
|
|
Related Products |
-
CoolMaster 1000D
CoolMaster 1000D - RS232 Interface Adapter for Daikin VRV AC System.
-
CoolMaster 2000S
CoolMaster 2000S - RS232 Interface Adapter for Sanyo VRF AC System.
-
CoolEx Modbus
CoolEx is a Modbus I/O extender with analog, digital and PWM
inputs and outputs. CoolEx has six variable Analog Outputs,
six PWM outputs, Digital (on/off) Inputs and Outputs,
Connection to VRV/VRF Air Conditioning System Line.
|
|
|